The Procal 5000 continuous emission monitoring analyser is designed for in stack analysis of gas phase stack emission components. Utilising absorption spectroscopy the instrument stores and analyses a full UV spectrum and using advanced mathematical techniques calculates the emission concentrations. The Procal 5000 system is a fully integrated stack gas analyser with built in auto zero/calibration facilities. The instrument will report concentrations of stack gas pollutants either through the Procal Analytics Analyser control Unit (ACU) or Personal Computer (PC) running Procal Analytics Analyser Control Windows (ACW) software.
An-in stack heater (ISH) is optionally supplied when process conditions are liable to result in water vapour condensing in the analyser sample cell. The on stack analyser consists of two main parts:
The main instrument housing, which is manufactured from cast aluminium and rated to IP65 \ NEMA 4X. This custom designed housing has many benefits including two separate compartments, ribbed cooling fins to allow good heat dissipation and hinged covers for easy maintenance. The main upper compartment houses the optical components consisting of an ultra violet source and Procal designed and manufactured robust diode array spectrometer. In a second compartment with separate access a mains power supply, microprocessor and auto zero \ calibration module are located.Procal Analytics unique in-situ sample cell with its auto/zero calibration capability is attached to the aluminium housing. The use of the advanced in-situ sample cell thereby avoids the need to extract a sample from the stack. Thus, the use of costly high maintenance sample handling systems is eliminated.

Sintered stainless steel filter panels fitted to the sides of the in-stack measuring cell allows the permeation of stack gas whilst preventing the ingress of dust and particulates. The envelope thus formed allows the introduction of zero and span gas enabling the system to be fully verified on stack. Complies with US EPA 40 CFR part 60 and 75. The Analyser Control Unit (ACU), or a PC running Procal analyser control software for Windows displays gas concentrations of each of the monitored components along with information on sample condition diagnostic data and trends. The information can be retransmitted in the form of 4 - 20mA current outputs (one per
measured component), parallel printer output and optional RS232C serial output. The ACU or PC can support up to four optical head units of any Procal analyser type. Analyser control unit (ACU) data sheet 7-3008 Analyser control software for PC (ACW) data sheet 7-3023The analyser controls an integral auto zero unit. On command the unit will check and if necessary adjust zero by introducing instrument air into the probe thereby forcing out sample gas and establishing a true zero. If required the unit can then introduce a known concentration of test
gas into the sample cell thereby establishing the calibration point, if required the unit will then auto calibrate. In the event of power loss to the analyser or too low sample temperature the integral auto zero unit will purge the sample cell with air. This is done to prevent highly corrosive condensates forming in the sample cell. If the analyser is to operate in a stack or duct near or below dew point an optional in-stack heater is fitted: The temperature of this unit is controlled by an output

 

 

 

P5000 series

 

 

 

 

 

 

 

 

 
     
   

 

Analysers Dust Monitors  NOx Analyser SO2 Analyser TESTO Procal  PCME Procal Analytics CO Phoenix Instrumentation CO2 Analyser Gas Monitor EPA Analyser Opacity Monitor DECC 40CFR Part60 PS1 PS2 PS3 PS4 PS5 PS6 PS7 PS8 PS9 PS10 PS11 CEM1 CEM2 CEM3 CEM4 CEM5 CEM6 CEM7 CEM8 CEM9 CEM10 CEM11 BROKEN BAG DETECTOR PARTICULATE MONITOR DUST MONITOR FILTER FAILURE testo 335 testo 327 testo 325 testo 330 testo 350 procal P200 procal P5000 Stack analyser emission analyser stack gas phoenix instrumentation environmental analyser instrumentation SO2, CO, CO2, NO, NO2, HC VOC TESTO NOX analyser

sulphur dioxide nitric oxide carbon dioxide hydro carbons volatile organic compounds h2o TRS NOx NOx analyser phoenix testo procal pcme dust opacity gas analyser monitor detector combustion analyser exhaust gas analyser portable gas analyser dt270 dt770 dt373 dt99 dt991 lms 181 da50 ds10a ds10c ds10 ds30 ds30a ds30c ds30 electrodynamic triboelectric scintillation testo procal pcme phoenix gas analyser emissions analyser nox analyser so2 analyser environmental instrumentation flue gas analyser CEM's continuous emission monitor